Hey there! As a supplier of submersible level gauges, I often get asked about the installation process, especially in unique tank shapes like semi - circular ones. In this blog, I'll walk you through how to install a submersible level gauge in a semi - circular tank step by step.

Why a Submersible Level Gauge?

Before we dive into the installation process, let's quickly talk about why a submersible level gauge is a great choice for your semi - circular tank. These gauges are super reliable and can accurately measure the liquid level in the tank. They work based on hydrostatic pressure, which means they can handle different types of liquids, whether it's water, oil, or chemicals. You can check out our Hydrostatic Level Gauge for more details on how it works.

Tools and Materials You'll Need

First things first, gather all the tools and materials you'll need for the installation. Here's a list:

Pre - installation Checks

Before you start the actual installation, it's important to do some pre - installation checks.

  1. Tank Inspection: Take a good look at the semi - circular tank. Make sure there are no sharp edges or rough surfaces that could damage the submersible level gauge. Check for any signs of corrosion or leaks in the tank.
  2. Gauge Inspection: Examine the submersible level gauge for any visible damage. Check the cable for cuts or frays. Make sure all the connections are tight and in good condition.
  3. Location Selection: Decide where you want to install the gauge in the tank. The ideal location is usually in the center of the tank, but since it's semi - circular, you need to consider the flow of the liquid and the shape of the tank. Avoid areas where there are strong currents or where debris might accumulate.

Installation Steps

Step 1: Mounting the Bracket or Chain

If you're using a mounting bracket, attach it securely to the top of the tank. Make sure it's level and can support the weight of the submersible level gauge. If you're using a chain, tie it to a strong point at the top of the tank. The chain should be long enough to allow the gauge to reach the desired depth in the tank.

Step 2: Lowering the Gauge

Carefully lower the submersible level gauge into the tank using the chain or the bracket. Make sure the gauge is vertical and not touching the sides of the tank. Use the measuring tape to ensure that the gauge is at the correct depth. The depth will depend on the size of the tank and the range of the gauge.

Step 3: Connecting the Cable

Once the gauge is in place, connect the cable to the monitoring system. Make sure the connection is tight and secure. You may need to use a wrench to tighten any fittings. Check the polarity of the connections to avoid any electrical issues.

Step 4: Testing the Gauge

After connecting the cable, it's time to test the gauge. Fill the tank with a small amount of liquid and check the readings on the monitoring system. Make sure the readings are accurate and consistent. If there are any issues, double - check the connections and the installation of the gauge.

Post - installation Checks

After the installation is complete, there are a few post - installation checks you should do.

IMG_0332IMG_0335

  1. Leak Check: Check for any leaks around the cable entry point or the mounting bracket. If you find any leaks, seal them immediately to prevent any damage to the gauge or the tank.
  2. Calibration Check: Verify the calibration of the gauge. You can do this by comparing the readings on the gauge with a known level in the tank. If the readings are off, you may need to recalibrate the gauge.
  3. Monitoring System Check: Make sure the monitoring system is working properly. Check the alarms and the data logging functions. Make sure you can access the data remotely if needed.

Troubleshooting

Even after a successful installation, you may encounter some issues with the submersible level gauge. Here are some common problems and their solutions:

  • Inaccurate Readings: This could be due to a calibration issue, a damaged gauge, or interference from other equipment. Check the calibration, examine the gauge for damage, and make sure there are no sources of interference.
  • No Readings: If there are no readings on the monitoring system, check the power supply, the cable connections, and the gauge itself. Make sure the gauge is properly submerged in the liquid.
  • Alarm Activation: If the alarms are going off when they shouldn't be, check the alarm settings and the calibration of the gauge. Make sure the alarm thresholds are set correctly.

Maintenance Tips

To keep your submersible level gauge in good working condition, here are some maintenance tips:

  • Regular Cleaning: Clean the gauge regularly to remove any debris or sediment that may accumulate on it. You can use a soft brush and a mild detergent to clean the gauge.
  • Cable Inspection: Check the cable for any signs of wear and tear. Replace the cable if it's damaged.
  • Calibration Checks: Periodically check the calibration of the gauge to ensure accurate readings.

Conclusion

Installing a submersible level gauge in a semi - circular tank may seem a bit tricky, but if you follow these steps and do the necessary checks, it can be a smooth process. Our submersible level gauges are designed to be easy to install and reliable. If you're interested in purchasing a submersible level gauge for your semi - circular tank or have any questions about the installation process, feel free to reach out to us for a chat and we can discuss your specific needs.