Membrane Dissolved Oxygen Meter

Membrane Dissolved Oxygen Meter

Measurement range: Dissolved oxygen 0-25.00mg/L;
Temperature: 0-60 ℃;
Measurement error: Dissolved oxygen ± 1% F • S;
Temperature: ± 0.5 ℃
Automatic temperature compensation: 0-60 ℃;
Products Description

 

Industrial dissolved oxygen meter (hereinafter referred to as the instrument) is an online water quality monitoring instrument with a microprocessor. Widely used in industrial water, domestic water, sewage treatment, as well as animal husbandry. Continuous monitoring and control of oxygen content in aqueous solutions.

The instrument adopts an LCD display screen; Intelligent Chinese menu operation; Has current or voltage output, freely adjustable measurement range, high and low limit alarm prompts, two sets of relay control switches, and adjustable hysteresis range; Automatic or manual temperature compensation, electrode automatic calibration.

 

-05

 

Structural Features And Working Principles

Structural features:

The entire measurement system mainly consists of two parts: an instrument (secondary meter) and a dissolved oxygen electrode (primary meter). The dissolved oxygen electrode contacts the measured solution, and the instrument displays the oxygen content, temperature, and working status of the aqueous solution.

 

Working principle:

The oxygen electrode uses platinum (Pt) as the cathode, Ag/AgCl as the anode, 0.1M potassium chloride (KCl) as the electrolyte, and a silicone rubber permeation membrane as the breathable membrane. When measuring, a polarization voltage of 0.68V is applied between the anode and cathode. Oxygen is consumed at the cathode through the permeation membrane, and the amount of oxygen passing through the membrane is directly proportional to the concentration of dissolved oxygen in water. Therefore, the limit diffusion current between the electrodes is directly proportional to the concentration of dissolved oxygen in water. The instrument detects this current and converts it into oxygen concentration through calculation. At the same time, the thermistor detects the temperature of the solution and compensates for the temperature of oxygen concentration.

The electrode reaction on the electrode is:

Cathode (Pt) O2+2H2O+4e=4OH-

Anode (Ag) 4Ag+4Cl -=4AgCl+4e

 

Technical Parameters

Measurement range Dissolved oxygen 0-25.00mg/L; Power supply 85~265VAC ± 10%, 50 ± 1Hz, power ≤ 3W; 9-36VDC, power ≤ 3W (optional);
Temperature 0-60 ℃; External dimensions 96 x 96 x 130mm;
Measurement error Dissolved oxygen ± 1% F • S; Installation method Disk mounted (embedded);
Temperature ± 0.5 ℃ Opening size 91 x 91mm;
Automatic temperature compensation 0-60 ℃; Instrument weight 0.5kg;
Residual electrode signal < 1 ‰; Environmental temperature -10~60 ℃;
Response time (final value 90%) < 60S at 25 ℃; <30S at 35 ℃; Relative humidity not more than 90%;
Stability Drift<2% F • S per week under constant pressure and temperature; No strong magnetic field interference around except for the Earth's magnetic field  
Signal output 0-10mA (load resistance < 1.5K Ω); 4-20mA (load resistance < 750 Ω); 20-4mA (load resistance < 750 Ω); Instrument size (see user manual or call for consultation)  
Two sets of relay control contacts 3A 240VAC, 3A 28VDC or 120VAC;    

 

-11

-17

22
23
24
25

 

-23

-26

 

Hot Tags: membrane dissolved oxygen meter, China membrane dissolved oxygen meter manufacturers, suppliers, factory, Dissolved Oxygen Meter In Water Quality, dissolved oxygen meter, Portable Dissolved Oxygen Meter, Handheld Dissolved Oxygen Meter