Online Ph Meter
video
Online Ph Meter

Online Ph Meter

Model: YP-510
Measurement parameters: pH/ORP;
Measurement range: pH 0-14pH
ORP: -1999-+1999mV;
Resolution pH: 0.01pH, ORP 1mV;
Products Description

 

The microcomputer industrial control instrument is a precision instrument used for testing the pH value of solutions. Its features of full functionality, stable performance, and easy operation make it an ideal instrument for industrial enterprises in the field of pH testing and control. The instrument adopts LCD display with background light.

 

-05

 

Technical Parameters

Model YP-510 Output signal 4-20mA isolation protection output, maximum load 500 Ω
Measurement parameters pH/ORP; Output mode ON/OFF relay output contact, 220V, 5A
Measurement range pH 0-14pH The hysteresis of the relay can be freely adjusted
ORP -1999-+1999mV; Signal input impedance ≥ 1 × 1012 Ω
Resolution pH 0.01pH, ORP 1mV; Working voltage 220VAC ± 10%, 50/60Hz
Precision pH ± 0.05pH, ORP ± 1mV; External dimensions 96 * 96 * 110mm
Standard solution pH 6.86/4.00/9.18 or 7.00/4.01/10.00 Opening size 92 * 92mm
ORP arbitrary standard solution Weight 0.6Kg
Temperature compensation automatic (Pt1000/Pt100) or manual Working environment temperature -5~55 ℃
Temperature compensation range 0~99.9 ℃ Relative humidity of air ≤ 90%
Working temperature -5~65 ℃ There is no strong magnetic field interference around except for the Earth's magnetic field  
Display screen 70 * 50mm large backlit LCD display    

 

Introduction To Ph Meter Electrodes

1. PH electrodes can be used for measuring various types of wastewater or most water quality analysis data.

2. The electrode can be used in conjunction with various acidity meters.

3. The electrode adopts cable BNC standard connectors or Y-shaped wiring terminals, etc. 4. If the electrode life is normally used for two years, it will be shortened due to harsh environment or improper maintenance.

 

Usage, maintenance and precautions

1. When measuring, it should be washed in distilled water (or deionized water) first, and the water should be absorbed with filter paper to prevent impurities from entering the measured liquid. The electrode bulb and liquid network should be immersed in the measured liquid at the same time.

2. When the electrodes are not in use, they should be cleaned and covered with a protective cover.

3. Electrodes should be avoided from long-term immersion in distilled water, protein solutions, and acidic chloride solutions, and should be prevented from coming into contact with silicone oils.

4. For electrodes that have been used for a long time, their glass film may become semi transparent or have sediment attached. In this case, they can be washed with 6M hydrochloric acid and rinsed with water.

5. It is recommended that users clean the electrodes once a week and cooperate with instrument calibration.

6. If you still cannot perform calibration procedures on the electrode using the above methods for maintenance and upkeep, the electrode will no longer be able to recover its response. Please replace the electrode.

 

-11

-17

22
23
24
25

 

-23

-26

 

Hot Tags: online ph meter, China online ph meter manufacturers, suppliers, factory, water quality analyzer for public health protection, water quality analyzer for traditional commerce, water quality analyzer for generalization, water quality analyzer for specialization, water quality analyzer for digitalization, water quality analyzer for quality assurance