Measurement range: 0.01L/s-10m³/s
Accumulated traffic: 999999999999m³
Distance measurement range: 0.35-3m (blind spot 0.35-0.5m)
Distance measurement accuracy: ± 3mm (flow accuracy of 1% depends on the type of weir plate)
Flow accuracy: ± 5% (1% to 3% of the uncertainty in the amount of water used in the weir groove, with an additional instrument measurement error of 1% to 2%)
Products Description

 

This instrument can directly display instantaneous flow rate and cumulative flow rate.

Built in digital memory to ensure data is not lost after a power outage.

It can be matched with various national standard weirs or troughs and can be widely used for measuring or monitoring the total amount of water quality discharge. This instrument is easy to operate and has multiple standard weir groove calculation methods built-in, making setup more convenient.

Optional communication interface, can be connected to data acquisition instrument, DCS, PLC system.

Non contact instruments have a longer service life.

 

-05

 

Technical Parameters

Measurement range 0.01L/s-10m³/s Analog output 4-20mA (output content: flow or liquid level)
Accumulated traffic 999999999999m³ Digital output RS485 (Modbus. rtu protocol)
Distance measurement range 0.35-3m (blind spot 0.35-0.5m) Power supply voltage AC power supply: AC220V;
Distance measurement accuracy ± 3mm (flow accuracy of 1% depends on the type of weir plate) DC power supply DC12V, DC24V (customizable wide power supply mode)
Flow accuracy ± 5% (1% to 3% of the uncertainty in the amount of water used in the weir groove, with an additional instrument measurement error of 1% to 2%) Environmental temperature Main unit: -5 ℃~45 ℃;
Distance measurement resolution 1mm Sensor section -30 ℃ to 40 ℃
Pressure atmospheric pressure Protection level Host part: IP66 (pay attention to tightening the lower electrical interface to prevent dust and moisture);
Instrument display Equipped with LCD display for instantaneous and cumulative flow rate, in months, days, hours, minutes, and seconds Sensor part IP67 (fully sealed sensor IP68)
Clock error <0.05% (calibrated when larger)    