Products Description
The main functions of a water quality analyzer include monitoring water quality indicators, detecting pollutants, and developing water quality standards. It can measure various indicators in water, such as pH/ORP value, dissolved oxygen, turbidity, residual chlorine, conductivity, etc., in order to comprehensively understand the basic condition of water quality. The monitoring of these indicators is crucial for assessing the health status of water bodies and helps to timely detect and address water quality issues. This includes real-time monitoring of water quality measuring instruments such as sludge concentration meters and sludge interface meters, as well as control of related process flows. It further optimizes sludge discharge control and dosing control to prevent deterioration of effluent, avoid sludge denitrification and decomposition, and optimize process control flow. All kinds of instruments can be connected to PLC and DCS systems through 4-20mA or RS485 (Modbus protocol), and can also choose to output switch signals to connect to the automatic control system, providing real-time data and automatic control for industrial automation operation.
FAQ:
1.Q:What's the shipping method?
A:By express way, such as Fedex, DHL, TNT and so on; by air; by sea. Shipping cost is decided by shipping ways& product actual weight &volume and your detailed address.
2.Q:What's the Payment method?
A: We support various payment way(T/T, Visa card, Western union, Moneygram, Secure payment-Escrow, etc.) T/T
3.Q:Can we print our own brand or logo on your products?
A: Yes, it is our pleasure to be one your OEM manufacturer in China to meet your OEM request
4.Q: Why do some goods have difference between website picture and practical items?
A: Because difference of light and browser, also different batches, material may be little difference. If any question, please tell us before order and ask clearly.
Due to the different prices of precision instruments made with different parameters, we need you to provide our sales team with more detailed instrument parameters, which will be beneficial for us to provide you with prices and appropriate discounts.

Water quality analysis and measurement instruments play an important role in various fields such as environmental protection, industrial production, sewage, and water treatment, such as power plants, purified water plants, water plants, domestic sewage treatment plants, beverage plants, aquaculture, and environmental protection departments. It can be connected to various brands of PLC systems or secondary control systems through 4-20mA or RS485 (custom protocol or Modbus protocol), providing real-time measurement data for industrial automation operation and environmental protection.
Technical Parameters
| Measurement project | pH ORP TEMP | Communication output | RS485 |
| Measurement range | 0~14pH -2000mV~2000mV -10~135 ℃ | Input impedance | ≥ 1 × 1012 Ω |
| Resolution | 0.01 pH 1mV 0.1 ℃ | Alarm indication | Two sets of alarm lights display high and low points |
| Accuracy | ± 0.01pH ± 1mV ± 0.2 ℃ | Power supply | 220VAC, 50Hz, or 24VDC (see product identification) |
| Stability | ≤ 0.02pH/24h ≤ 1mV/24h ≤ 0.2 ℃/24h | Power | 3W |
| Standard solution | 6.86/4.00/9.18 Or any standard solution of 7.00/4.00/10.00/ Two point calibration or one known concentration calibration Two point calibration/ | External dimensions | 235 * 210 * 115mm |
| Correction range | Zero point ± 1.50pH, slope ± 30% | Installation method | Wall mounted installation |
| Temperature compensation | manual temperature compensation or Pt1000 automatic temperature compensation | Weight | 0.65Kg |
| Display | 128 * 64 dot matrix Chinese display | Working environment temperature | -5~55 ℃ |
| Control mode | Hi/Lo, two independent relay control outputs; | Relative humidity of air | ≤ 90% |
| Relay load maximum | AC 220V, 3A resistive load | No strong magnetic field interference around except for the Earth's magnetic field | |
| Signal output | 4-20mA isolated signal output, programmable, maximum load 500 Ω |
Matters Needing Attention
1. Please carefully read and understand the user manual before installation to avoid incorrect wiring that may cause damage to the instrument.
2. Please choose a well ventilated location for installation, pay attention to the waterproofing of instruments and cables, and avoid using them in corrosive environments.
3. Do not power on the instrument until all wiring is completed to avoid accidents.
4. The transmission of electrode signals must use RG58 high insulation special coaxial cables and cannot be replaced by ordinary wires casually, otherwise incorrect measurement results will be generated.
5. The controller inside the instrument is a low current relay. If you want to control equipment with high power, please connect an external relay with a high current capacity to avoid burning out the internal relay of the host.
Instrument size (available in panel mounted and wall mounted forms, please feel free to inquire by phone)








Hot Tags: Independent output ORP meter, China Independent output ORP meter manufacturers, suppliers, factory, orp meter, Online Ph orp Meter, Orp Meter for Drinking Water