Products Description
The integrated electromagnetic digital flowmeter is based on Faraday's electromagnetic induction law and is used to measure the volume flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an induction instrument for measuring the volume flow rate of conductive media. In addition to measuring the volume flow rate of general conductive liquids, it can also be used to measure the volume flow rate of strong corrosive liquids such as strong acids and alkalis, as well as homogeneous liquid-solid two-phase suspensions such as mud, slurry, and pulp.

Application Site
Corrosion resistance, capable of measuring almost any conductive liquid;
Strong anti-interference ability, almost unaffected by external interference;
Measurement is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity;
The requirement for measuring the unobstructed flow components and pressure loss free straight pipe section inside the pipeline is low. Has unique adaptability to slurry measurement;
There are no movable components or flow blocking components inside the measuring tube, and there is almost no additional pressure loss during the measurement;
Equipped with self inspection and self diagnosis functions;
On site, the range can be modified online according to the actual needs of the user;
Display Section
LCD backlight display: instantaneous flow rate, cumulative flow meter, etc; One click query for net cumulative value, positive cumulative value, negative cumulative value, and current conductivity equivalent value; Multiple units can be switched (L, m?, Kg, t/s, min, h); 485 communication for remote data reading.
Technical Parameters
| Accuracy level | ± 0.5% R (0.5 ‰), nominal pressure: 4.0MPA (DN10-DN150), 1.6MPA (DN200-DN600), 1.0MPA (DN700-DN1200) (other specifications can be customized) | Lining material | Neoprene rubber (CR); Polytetrafluoroethylene (F4); Polyurethane rubber (PU); Polytetrafluoroethylene propylene (F46); |
| Installation method | flange installation (default); Support installation (customized), clamp installation (customized); | Range ratio | 201; |
| Electrode type | 316L electrode (standard configuration); HB/HC alloy electrodes (in strong acidic and alkaline environments); Titanium electrode; Tantalum electrode; Tungsten carbide electrode; Platinum electrode; | Working environment | Sensor -25-180 ℃; Converter: -10-60 ℃ (customized for ≥ 80 ℃); |
| Lining material | Neoprene rubber (CR); Polytetrafluoroethylene (F4); Polyurethane rubber (PU); Polytetrafluoroethylene propylene (F46); | Fluid requirements | Conductive medium (conductivity ≥ 5US/CM liquid); |
| Range ratio | 20:1; |








Hot Tags: electromagnetic digital flow meter, China electromagnetic digital flow meter manufacturers, suppliers, factory, Battery Powered Electromagnetic Flow Meter, electromagnetic flowmeter, Battery Operated Electromagnetic Flow Meter, Adept Electromagnetic Flow Meter, Electromagnetic Digital Flow Meter