Submersible Liquid Level Transmitter
video
Submersible Liquid Level Transmitter

Submersible Liquid Level Transmitter

Working temperature: 0℃~100℃;
Basic error
The accuracy level of the transmitter is divided into:
0.3 level, basic error is ±0.3;
0.5 level, basic error is ±0.5 (basic error is expressed as a percentage of the range).
Products Description

 

Submersible level transmitter is a sensor used to measure the liquid level. It uses the principles of pressure sensor, capacitance, etc. to convert the liquid level into analog output. After connecting to the control system, the liquid level can be monitored in real time and relevant data can be output. Submersible level transmitters are usually suitable for liquid level detection inside containers such as storage tanks and warehouses. It can be directly immersed in the liquid and the current liquid level can be calculated by measuring the pressure value under the liquid. Due to direct contact with the liquid, corrosion resistance and explosion-proof properties are required. Submersible level transmitters can be connected to various control systems to realize remote monitoring, control and alarm functions. It has a wide range of applications, including chemical, pharmaceutical, food, water treatment, environmental protection and other industries.

 

-05

 

Technical Parameters

Working temperature 0℃~100℃; Thermal sensitivity drift When the ambient temperature deviates from the reference working condition temperature, the full scale drift of the transmitter should not exceed 0.03%FS/℃.
Basic error   Insulation resistance Under the reference working conditions, the insulation resistance between each terminal of the transmitter and the ground shall not be less than 20MΩ/250V.
The accuracy level of the transmitter is divided into 0.3 level, basic error is ±0.3; 0.5 level, basic error is ±0.5 (basic error is expressed as a percentage of the range). Explosion-proof performance The explosion-proof performance of the instrument meets the requirements of ExiaⅡCT4.
Thermal zero drift When the ambient temperature deviates from the reference working condition temperature, the zero drift of the transmitter should not exceed 0.03%FS/℃. 4-20mA non-polarity connection  
Thermal sensitivity drift When the ambient temperature deviates from the reference working condition temperature, the full scale drift of the transmitter should not exceed 0.03%FS/℃. Multi-level electrical protection  
Insulation resistance Under the reference working conditions, the insulation resistance between each terminal of the transmitter and the ground shall not be less than 20MΩ/250V.    
1111

1

 

-11

-17

22
23
24
25

 

-23

-26

 

Hot Tags: submersible liquid level transmitter, China submersible liquid level transmitter manufacturers, suppliers, factory, Submersible Liquid Level Sensor, Hydrostatic Level Gauge, Input Type Static Pressure Liquid Level Transmitter, submersible level gauge, Static Pressure Input Liquid Level Gauge